WIRE WELDING
Connecting UWF-102 to UWI-500 TP and shielding gas The wire feeder is delivered with the required hoses and cables for connection to shielding gas and
UWI-500 TP
4m hose for shielding gas is connected here: The other end has nut with 3/8" RH threads for connection to a shielding gas regulator on a gas cylinder.
4m remote control cable for connection to the back side of UWI-500 TP is connected here: The 4m connection cable for welding current is connected here:
NOTE:
Correct polarity for the welding process must be selected when connecting the welding cables to correct polarity for welding and return at the power source.
If cable extensions are used the return cable should If cable extensions are used the return cable should also be extended to the work place for polarity also be extended to the work place for polarity selection there.
selection there.
The welding cable shuld always be connected to the + The welding cable shuld always be connected to the + or – terminals on front panel of UWI-500 TP to ensure or – terminals on front panel of UWI-500 TP to ensure that correct polarity for the wire is used is used. that correct polarity for the wire is used is used. Positive + polarity is normally used for gas-shielded Positive + polarity is normally used for gas-shielded wires wires.
Negative – polarity is normally used for self-shielded Negative – polarity is normally used for self-shielded wires.
wires.
The 4m control cable from UWF-102 is connected at the back of the UWI-500 TP here: