Transfer the contents of Base and Activator containers from the respective jars into the mixing container provided. Mix in the raio indicated. Lids should be replaced immediately after use. The two components should be thoroughly mixed until completely streak free and a uniform colour is achieved, using the spatula provided.
All equipment should be cleaned IMMEDIATELY after each use with a cleaner. Failure to follow this procedure will result in application equipment becoming unusable.
3. Application
Prepared Surfaces should be dry. Using the spatula provided the mixed material should be spread evenly onto the prepared area, working the material into any cracks and surface defect. Once the CeramiGrade Rebuild has reached initial set the material can be separated from surfaces treated with release agent.
3.06
When CeramiGrade Rebuild is being used to repair leaking pipes, the flow through the pipe should be discontinued until the repair is made and the CeramiGrade Rebuild is set. Any leaking fluid must be wiped from the prepared surface before undertaking the repair. When a second coat is required, this should be done as soon as the first coat has set. (within 4 hours)
6. Health and safety
As long as normal good practices are observed CeramiGrade Rebuild can be safely used. A fully detailed Material Safety Data Sheet is included with the set. The information provided in this Instruction sheet is intended as a general guide only. Users should determined the suitability of the product for their own particular purposes by their own tests.
Corroded tube plates
4. Machining
Once the CeramiGrade Rebuild has cured for the minimum time indicated in the Curing Properties Section of the product specification sheet, sanding, grinding and machining etc. can be carried out using standard engineering practices.
Eroded impellers